18.7 C
New York
Tuesday, August 19, 2025

Charged EVs | HIL simulation’s essential position within the 800 V EV transition


Sponsored by Pickering Interfaces.

The following energy structure of selection for EVs is 800 V, which requires parts to be suitably rated and extra sturdy than their 400 V counterparts. Nonetheless, most check tools used for 400 V EV system growth will be re-used for 800 V if it will possibly deal with the upper voltages, making the transition simpler for EV builders.

Obtain the white paper for additional info

The Advantages of {Hardware}-in-the-Loop and Simulation

In EV growth, many corporations use {Hardware}-in-the-Loop (HIL) Simulation as a part of a test-driven technique. HIL simulation permits {hardware}, comparable to a Battery Administration System (BMS), to work together with a simulated setting that mimics real-world situations, together with bodily elements like temperature and dynamic situations like movement and vibration. This helps engineers observe system habits beneath reasonable eventualities.

Simulating these real-world situations allows early identification of design flaws and weaknesses, permitting for well timed enhancements and avoiding expensive points later in growth. A key benefit of simulation in EV growth is the power to securely create excessive fault situations—comparable to fast discharging and quick circuits—to judge BMS habits with out risking harm to precise battery packs.

Making a HIL Check Platform

Whereas a HIL check platform may very well be created from scratch, the fee (each financial and time) of doing so tends to be prohibitive within the automotive {industry}. Subsequently, using an industry-standard platform is extremely really helpful. Two requirements to contemplate are PXI and LXI, that are based mostly on the PCI and Ethernet {industry} requirements, respectively.

Each are supported by a lot of international distributors with many industrial off-the-shelf merchandise obtainable. Each present seamless vendor-independent plug-and-play. Of nice profit is that product longevity is assured, and the distributors have obsolescence administration processes in place. 

400 to 800 V Testing Migration Path

Many OEMs and programs homes within the automotive sector have invested in growth and verification tools, together with HILS programs, for EVs. The excellent news for these utilizing PXI or LXI platforms is that many current modules will nonetheless be usable when transitioning from a 400 V to an 800 V structure, permitting for vital reuse of the check system.

For parts that want alternative attributable to greater voltage scores, PXI and LXI’s modularity and scalability make it simple to swap them out for upgraded variations.

Beneath, we talk about a couple of Pickering Interfaces merchandise appropriate to be used in 800V architectures.

Battery Cell Simulation

Cell-level simulation is important for EV growth, because it permits the Battery Administration System (BMS) to acknowledge a completely charged pack precisely. This requires simulating particular person 3.2 to three.7 V cells and stacking them to attain the required voltage—96 cells for 400 V and 192 cells for 800 V.

The BMS additionally manages cell balancing, necessitating the power to simulate every cell’s cost stage throughout relaxation, charging, discharging, and introducing imbalances.

By simulating cells independently, current tools will be tailored for 400 V and 800 V architectures by including extra modules (simulated cells) so long as the emulator can deal with greater voltages.

Determine 2 exhibits the block diagram of a multi-channel battery simulator module obtainable in PXI (41-752A) and PXIe (43-752A). It contains a number of energy provide channels (two, 4 or six per slot) able to supplying as much as 7V and 300mA, that are remoted from each other and from system floor. Subsequently, the module’s energy provides can be utilized to emulate a stack of battery cells. Additionally, every channel can sink as much as 300mA to emulate a battery beneath cost. Every channel gives unbiased energy and sense connections, permitting the simulator to sense a distant load and proper for wiring losses.

Determine 2 – Above, a block diagram of the 41/43-752A 6-channel battery simulator module.

Excessive Voltage Switching

Excessive voltage switching is utilized in check programs for connecting or disconnecting indicators and routing them between factors, achieved by three configurations:

  • Uncommitted switches (e.g., single-pole, single-throw, usually open or closed).
  • Matrices that join any enter to any output.
  • Multiplexers (MUXs) that join a single enter to a number of outputs.

These configurations are available numerous relay and connection counts, with modules able to switching a number of kV, making them appropriate for purposes like isolation switching and breaker simulation.

Excessive-voltage switching will be achieved utilizing a number of options from Pickering Interfaces: over 60 PXI/PXIe modules and 28 LXI modules. For instance, the 40-323-901 (PXI) and 42-323-901 (PXIe) are 14xSPST relay modules appropriate for high-voltage energy switching purposes. They’ll deal with present as much as 0.25 A for chilly switching as much as 9 kVDC (9 kVAC peak) and for warm switching as much as 7.5 kVDC (7.5 kVAC peak). 

RTD Simulation

Temperature have to be monitored at numerous areas in an EV, together with the battery pack, motors, energy inverter, charger port, and cabin. A well-liked and cost-effective choice is the resistance temperature detector (RTD), with the PT100 being a standard kind with a resistance of 100Ω at 0°C. RTDs can have both a optimistic or unfavorable temperature coefficient (PTC or NTC).

Simulating RTDs is helpful since testing the design beneath a variety of temperatures would in any other case require costly environmental check chambers.

PXI-based RTD simulator modules can be found from a number of corporations. For instance, Pickering Interfaces has many appropriate modules for RTD simulation, together with the 40-263 (with 4, 8, 12, 16, 20 and 24 channels) that may simulate the resistance vary 40 to 900Ω, which equates to a temperature vary of -150 to 850oC, to a decision of lower than 10mΩ. Determine 3 exhibits an instance module.

To a lesser diploma, thermocouples are additionally utilized in EVs, primarily in product growth, attributable to their excessive accuracy. Their outputs, that are small voltages (a couple of millivolts), will be simulated. Pickering Interfaces presents PXI millivolt thermocouple simulator modules with 8, 16, 24, or 32 channels, offering extremely correct low-voltage sources. Every channel can function throughout three voltage ranges to simulate any customary thermocouple kind used within the {industry}.

Fault Insertion/Injection

The power to insert faults throughout system growth and verification is important. As talked about above, programs may must instigate a secure shutdown or, if redundancy is in-built, energy re-routed if a fault is detected. This performance must be absolutely validated.

Pickering Interfaces’ vary of PXI fault insertion models is explicitly designed for safety-critical purposes the place the habits of a management system, comparable to a BMS, must be totally evaluated beneath all potential real-world fault situations.

For instance, the 40-592 fault insertion break-out (FIBO) is a large-scale, high-density switching matrix. It’s one in all a variety of modules designed for purposes requiring the simulation of a wide range of faults in advanced designs with a excessive variety of indicators/connections, comparable to a battery pack.

Open circuits and quick circuits (to a different sign/part or to the bottom) are typical faults that may be simulated.

Abstract

Transferring from 400 to 800 V architectures presents advantages like greater efficiency and sooner charging. Nonetheless, it requires better sturdiness and security. Simulation is the most secure approach to confirm an EV’s structure and programs, permitting for simple check situations and outcomes traceability. Utilizing PXI and LXI-based check tools gives producers with a straightforward migration path. This permits optimizing key system parts and accelerates system growth by automated testing.

Obtain the white paper for additional info



Related Articles

LEAVE A REPLY

Please enter your comment!
Please enter your name here